What is a load switch and how is it used?

Disconnecting loaded electrical circuits always carries the risk of sparking. Load shedding on high-voltage lines is especially dangerous. A powerful electric arc formed when switching unprotected contact blades can lead to the destruction of power contacts and failure of electrical devices. A load switch equipped with devices for emergency arc extinguishing is capable of protecting the circuit switching process.

Load switches (LCBs) belong to those types of switching devices that, in terms of the level of permissible currents, occupy an intermediate position between conventional disconnectors and special rated current switches capable of cutting off overcurrents in emergency situations. Despite the fact that switching the rated current with a load switch is allowed, the device is not designed to switch off overload currents in the event of a short circuit. For these purposes, the use of special high-voltage fuses is provided.

Application

Load switches are used in distribution networks for the purpose of switching lines and power transformers operating at rated voltages. The devices can be used to switch on/off auxiliary loads, but are not intended to provide short-circuit protection unless fused designs are installed (see Figure 1).


Rice. 1. HV with fuses

High-voltage lines of 6 - 10 kV are equipped with such power disconnectors, for currents not exceeding 400 - 600 A. Relay devices are used to switch and protect more powerful power lines. In low-power networks, it is allowed to use HVs without fuses.

There are compact switches for loads up to 100 A, which are easily mounted in switchgears. Such switches are similar in appearance to the design of a circuit breaker (see Fig. 2) and are installed at the inputs of networks of apartment and private buildings. They are controlled only manually and do not turn off when the protection current reaches.


Rice. 2. Low power load switches

The presence of a modular power switch does not eliminate the need to protect wiring in emergency modes by other means. In particular, emergency shutdown of the home electrical network is provided by automatic batch switches, but it is not recommended to use them for frequent load shedding due to rapid wear of the contacts. In this sense, the load switch is more reliable, since its contacts are designed for such operating modes.

Autogas type load switch VNP-M1-10/630-20.

Load switch type VNP-M1-10/630-20

Load switches of type VNP-M1-10/630-20 are produced by the Nalchik High-Voltage Equipment Plant (Nalchik, Russia). Having undergone modernization, switching off the load has become safe to use. Intended for operation in cabinets of complete switchgear (KRU), in complete transformer substations (KTS), as well as in cells of stationary one-way and two-way service chambers (KSO) with a voltage of 10 kV three-phase alternating current with a frequency of 50 and 60 Hz for networks with grounded or isolated neutral. The switch is equipped with a built-in hand-wound spring drive, which is designed for both local and remote control.

Source: forca.ru

37153

Bookmarks

Comment 1

Latest publications

The chief engineer of the Kalugaenergo branch held working meetings with the heads of the rural settlements of Petrishchevo and Alekino in the Tarussky district

Today, at 14:55 17

Schneider Electric Introduces PowerLogic DVR Dynamic Voltage Compensator to Improve Power Quality and Reliability

Yesterday, at 00:24 25

Kalugaenergo received gratitude from the administration of the village of Betlitsa

February 7 at 11:25 32

Igor Makovsky visited the machine-building plant, part of the Rosatom State Corporation, to get acquainted with the installed industrial-class electricity storage system.

February 4 at 18:29 61

Customer technical support is a priority for ANTRAX Group of Companies

February 4 at 17:37 57

Udmurtenergo provided reliable power supply to the sports and recreation complex in the city of Votkinsk

February 4 at 16:59 97

Kurskenergo connected a large agricultural facility in the Kursk region to the networks

February 4 at 11:29 67

Schneider Electric expands digital renewable energy procurement capabilities globally with acquisition of Zeigo platform

February 4 at 10:45 41

Why is the premium segment of complex household equipment growing? Results of 2022

February 3 at 15:02 56

The trade union of the Kalugaenergo branch summed up the results of work in 2021

February 3 at 13:21 62

Comments 1

Advantages and disadvantages

The switching devices under consideration have strengths and weaknesses.

Benefits include:

  • lower cost compared to other types of switches;
  • fast and reliable switching on and off of rated load currents;
  • the possibility of using cheap fuses for overload protection;
  • The presence of a visible break in the contacts of high-voltage HVs, which makes it possible to do without an additional disconnector.

Flaws:

  • limited service life;
  • breaking the circuit is possible only for currents within the rated power values;
  • Once the fuse has tripped, it must be replaced.

Operating requirements

When operating this equipment, the following requirements must be met:

  • correct choice of element taking into account technical characteristics;
  • proper maintenance, in accordance with the requirements provided by the manufacturer;
  • compliance with operating conditions permissible for a specific device;
  • availability of trained and certified personnel allowed to service the equipment.

Installed devices must undergo regular inspections, tests and other necessary work as required.

Switch selection

Design and principle of operation

The design of a high-voltage load switch is very similar to the design of three-pole disconnectors. On the frame there are movable knives rotating in a vertical plane and having a sickle shape. They enter the chamber where the fixed contacts are located.

The rotation of the knives is controlled using mechanisms, manual drives, or semi-automatic devices. An electromagnetic drive using a solenoid provides remote load disconnection of high-voltage devices, and in some cases, operation in automatic control.

Figure 3 shows a drawing of a three-pole HV with a manual drive.


Rice. 3. Drawing of VNA load switch

Please note (drawing on the left) that the design provides for the installation of fuses that are not shown in the drawing. All live parts are separated from the frame by powerful insulators (picture on the right).

To ensure the required speed of contact separation, spring mechanisms are used. When the shaft turns, the spring accumulates potential energy, which at a certain moment is released, directing the accumulated power to the movement of the knives. The spring mechanism is clearly visible in Figure 4.


Rice. 4. VNA load switch with spring mechanism

The load switch kit may include stationary grounding blades. These additional protection elements have mechanisms to block erroneous actions by personnel.

The main difference between HVs and disconnectors is the presence of arc extinguishing devices that ensure the safety of fixed and moving contacts during switching. Extinguishing the electric arc, which inevitably ignites when the loaded circuit is turned off or on, occurs in arc-extinguishing chambers equipped with liners made of polymers. The arcs are extinguished by the flow of evaporation products of the liners, formed under the influence of high temperatures of the resulting discharge.

Depending on the design of the HV, the extinguishing principle may differ. It should be remembered that extinguishing chambers do not ensure the absolute absence of an arc, which, although for a very short period of time, still occurs. The task is to suppress the growth of the discharge as quickly as possible by eliminating the conditions for its existence.

The damping effect is achieved in various ways: by blowing ionized air from the contacts, filling the chambers with special mixtures of gases, or creating a vacuum. Depending on the principle of arc suppression, different types of switches are distinguished.

Oil switches

Figure 4 – Design of the oil switch

In arc extinguishing devices of oil switches, the arc is extinguished by means of its effective cooling in the flow of gas and steam generated during the decomposition and evaporation of the oil

Advantages:

  • Reliability
  • Simplicity of design and operation
  • Strength

Flaws:

  • Large dimensions
  • Fire hazard
  • Difficult to install

Kinds

According to the method of extinguishing the arc in the chambers, HVs are divided into the following types:

  • autogas;
  • SF6;
  • vacuum;
  • air;
  • oil;
  • electromagnetic.

Autogas (gas generating) switch

The device is intended for operational switching of power electrical equipment. Arc suppression occurs under the influence of gases generated in the extinguishing chamber. An insert made of urea-formaldehyde resin or polymethyl methacrylate, located inside the chamber, heats up at lightning speed at the moment the arc extinguishing contacts are switched. Under the influence of high temperature, the top layer of polymer evaporates, and the resulting flow of gases intensively extinguishes the electric arc.

The condition for evaporation of the liner is created by arcing contacts, starting the process of “longitudinal blowing”. In the on state, the rated current flows through the main contacts.

Autogas HVs are actively used in Russia and the CIS countries. They are used at substations and installed in switchgears of 6-10 kV power networks with an insulated neutral. Basically, they are installed where it is not economically profitable to use installations of another type, and the use of disconnectors is prohibited by the rules of the Electrical Installation Regulations.

This type of switches has the lowest cost and high maintainability. These advantages are contributing to the growing popularity of gas-generating circuit breakers.

Vacuum high voltage circuit breaker

A very effective, but expensive device that allows you to turn off not only rated load currents, but also overcurrents during a short circuit. The contacts of vacuum switches are located in a vacuum chamber with ultra-low pressure (about 10-6 - 10-8 N/m). The absence of gas creates a very high resistance, which prevents the arc from burning.

When the contacts are opened/closed, an arc still occurs (due to the formation of plasma from the metal vapors of the contacts), but it goes out almost instantly at the moment of crossing zero. Within 7 - 10 μ/s, vapors condense on the surface of the contacts and on other parts of the camera.

There are varieties:

  • vacuum circuit breakers up to 35,000 V;
  • devices for voltages exceeding 35 kV;
  • vacuum contactors for networks of 1000 V and above.

Main advantages:

  • switch operation in any position;
  • switching wear resistance;
  • stable work;
  • Fire safety.

The disadvantages include the relatively high cost due to the complexity of the camera production technology.

Gas-insulated HVs

In switching devices of this type, SF6 gas is used to extinguish the arc. The device operates on the principle of autogas switches, but instead of air, sulfur hexafluoride (SF6) with the addition of other gases is used to extinguish the arc.

SF6 gas enters the extinguishing chamber body from a hermetic container, which is not released into the atmosphere, but is reused. There are core and tank devices (see Fig. 5).


Rice. 5. Tank SF6 HV

The designs of such switches use built-in current transformers. Modern SF6 HVs can operate in ultra-high voltage switchgear, reaching 1150 kV.

Vacuum circuit breakers

Figure 2 – Design of a vacuum circuit breaker

The operating principle of a vacuum switch is based on the high dielectric strength of vacuum and its dielectric properties. At the moment the contacts open, an arc occurs in the gap between them due to the evaporation of metal from their surface. When the current passes through zero, the vacuum restores the dielectric properties and the arc no longer occurs.

Figure 3 – Operating principle of a vacuum circuit breaker

Advantages:

  • Ease of design and repair
  • Ability to work not only in a horizontal position
  • Reliability and long service life
  • Compactness
  • Low fire hazard

Flaws:

  • Small resource during short circuit
  • Risk of switching overvoltages
  • High price

Symbol and marking

To mark load switches, alphanumeric symbols are used, grouped into groups:

VN X-X-00/0-0 xx 0 X0.

Note that the given structure of the designation may differ in the markings of different types of structures.

Let's consider one of the options.

  • The first group of letters contains information about the type of switch. VN – load switch. Sometimes the letter H is missing, but in its place, and most often an X in the second position indicates the type of product or design option.

Letter designation of construction types:

  • M – oil;
  • MM – low oil
  • A – autogas.

(SF6 gas switches have their own designation structure).

Letter designation of execution options:

  • M – modernized;
  • P – spring drive;
  • P – manual drive;
  • E – electromagnetic.

An X in the third position can indicate the location of the drive:

  • P – right;
  • L – left.

In the fourth position (00) there are numbers indicating the rated voltage in kV.

5th position (/0) – rated shutdown current, in kA.

6th position (0) – rated (through) current of the switch.

7th position (xx) – location of grounding knives (sometimes climate version). p – behind the fuses, c – on the side of the grounding contacts.

8th position (0) – indicates the type of device sending the command to shutdown (if available).

9th position (X0) – climatic version and placement category.

Example: marking VVE - 15 - 25/ 680 - UZ means: Vacuum switch, with an electromagnetic drive, designed for voltage 15 kV, thermal current - 25 kA, rated current VN - 680 A, used in temperate climates, intended for indoor installations.

Figure 6 shows an example of the designation on the diagram.


Rice. 6. Designation on diagrams

Technical specifications

Load switches are characterized by three important parameters:

  • rated voltage;
  • thermal current;
  • rated current HV.

Other parameters are taken into account based on location conditions, the desired switching method and the choice of type of execution.

As an example, we provide a table of parameters for VN:

Product typeU nom, kVFuse typeI no. fuse, kA maximum current, kAWeight (without drive), kg
VNP-33PK-Z8031,550
20031,555
VN-16636
1036
VNP-166PK-6502062
802064
1602078
VNP-1610PK-103212,552
5012,565
10012,579
VNP-176PK-6502062
802064
1602078
VNP-1710PK-103212,552
5012,565
8012,579

Technical parameters of other types of load switches can be obtained from the seller or from other sources of information.

Automatic Circuit Breaker Systems

An automatic load switch is an electrical switching device. It is designed to conduct rated currents to the load and opens the circuit automatically if short circuit currents or currents exceeding the rated value occur. Also, some devices are capable of triggering when there is an unwanted decrease in the supply voltage when the power changes direction. Machines should not be used as toggle switches; their mechanism is not suitable for this; internal contacts may burn.

Connection

On power lines, HVs are placed in front of power transformers. If the technical documentation provides for the presence of disconnectors, they are installed after the HV.

In a multi-apartment electrical network, HVs are installed in distribution panels (if there is access) or in another accessible place, separately for each apartment.

In production workshops, it is advisable to install a mini switch near each machine to ensure the possibility of emergency shutdown.

In a household electrical network, load switches are usually installed in front of the meter, although they can also be installed after the meter. But always in front of protective devices - automatic machines, plugs, etc. As an example, we give a diagram for connecting a high-voltage voltage in a single-phase network.


Rice. 7. HV connection diagram in a home network

Air circuit breakers

Figure 5 – Air circuit breaker design

The principle of operation of the air circuit breaker is to extinguish the arc using a high-speed flow of compressed air directed into the blow channels. Under the influence of the air flow, the arc is stretched and directed into the blow channels, where it is finally extinguished.

Advantages:

  • High response speed
  • High fire safety
  • Long service life

Flaws:

  • High cost of equipment and installation (compressors, receivers, etc.)
  • The need for regular maintenance