Mercury 230 am 02 How to Take Readings • Information on the state register

Mercury 230 AM-01 meters are designed for commercial metering of active electricity in one direction in a three- or four-wire alternating current network and operate both independently and as part of an automated power supply system.

  • The Mercury 230 AM-01 meter takes into account active electricity in single-tariff mode on an accrual basis from the moment of commissioning;
  • The Mercury meter works only in the direction of increasing readings if there is any phasing violation of the connection of the meter's current circuits;
  • Mercury 230 AM-01 meters use an electromechanical reading device and an LED indicator for the presence and consumption of electrical energy.
  • The standard telemetry output allows you to operate the Mercury meter as part of an automated accounting system that has the ability to receive accounting information in telemetry pulses;

Mercury 230 AM-01Mercury 230 AM-02Mercury 230 AM-03

Expert opinion

Viktor Pavlovich Strebizh, lighting and electrical expert

Any questions ask me, I will help!

The main element of the electric meter is a microcontroller, which analyzes all signals and calculates the amount of energy consumed. If there is something you don’t understand, write to me!

Technical characteristics of the meter Mercury 230 AM-01

The RosEnergoSnab company offers to buy Mercury multi-tariff single-phase electricity meters - Mercury 230 AM-01 at factory prices from the warehouse or on order. Check the delivery time and cost of each batch of electricity meters produced by Incotex in our sales departments. Please note that the price will depend on the volume of purchase.

Electric meters Mercury 230 AM are designed for commercial metering of active electrical energy in one direction in a three- or four-wire alternating current network and operate both independently and as part of an automated power supply system.

  • metering of active electricity in a single-tariff mode on an accrual basis from the moment of commissioning;
  • work only in the direction of increasing readings in case of any phasing violation of the connection of the meter's current circuits;
  • Electric meters use an electromechanical reading device and an LED indicator for the presence and consumption of electrical energy.

The standard telemetry output allows you to operate an electricity meter as part of an automated accounting system that has the ability to receive accounting information in telemetry pulses; Design options

Basic and additional functions

Thanks to the presence of a multifunctional LCD screen, working with these devices does not cause much difficulty.

The device for stopping the counter Mercury 230 ART 01 has a number of features. The device for stopping the electricity meter 230 ART 01 works with the meter..

Each electric meter requires a separate approach, and it is very important to know how to correctly take readings from them.

Vitaly, no, I am not going to transfer the Smart Home system to Windows OS. I believe that the architecture of UNIX systems is more convenient for constructing automation systems of this kind, it is free, open, easier to manage by remote means, and provides more opportunities.

Specifications

FOR EVERYONE Join the video discussion. They find videos with us. We invite you to familiarize yourself with the most popular search queries for video clips over the past month.

  • reliable constructive protection against data falsification;
  • accounting data for several tariffs (depending on the design);
  • multifunctional capabilities;
  • high accuracy of data recording;
  • affordable price;
  • a large selection of modifications, with the ability to select the appropriate one depending on the expected operating conditions - the availability of functions for remote information transfer and connection to a centralized control network;
  • ease of installation and connection;
  • convenience of taking readings;
  • Possibility of individual adjustment to the maximum characteristics of the network.

Technical characteristics of the electric meter Mercury 230 am-01

Reading of electricity consumption readings from reading devices in various meter versions:

Expert opinion

Viktor Pavlovich Strebizh, lighting and electrical expert

Any questions ask me, I will help!

The standard telemetry output allows you to operate the meter as part of an automated accounting system, which has the ability to receive accounting information in telemetry pulses;. If there is something you don’t understand, write to me!

How to stop three phase

  • AR – a model that takes into account the active and reactive components of electricity at several tariffs, equipped with a liquid crystal display;
  • AM is a meter with a mechanical reading device that summarizes readings according to a single tariff plan.

The AR version is produced in the following modifications:

  • 00 R – transformer connection model with a working (maximum) electric current of 5 (7.5) A and an RS-485 interface;
  • 01 R – direct connection device with current characteristics of 5 (60) A;
  • 02 R – differs from the previous modification in the magnitude of the electric current – ​​10 (100) A;
  • 03 R – product with an electric current of 5 (7.5) A;
  • 01 CL, 02 CL, 03 CL - three similar devices in terms of technical characteristics, but equipped with a CAN interface and a PLC modem.

The AM version is represented by the following modifications:

  • 00 – connection requires the use of a transformer, current characteristics are 5 (7.5) A;
  • 01 – connects directly, electric current value – 5 (60) A;
  • 02 – current parameters differ from the previous model – 5 (100) A;
  • 03 – version with current characteristics similar to modification 00.

Performance characteristics – AM

The listed modifications differ in accuracy class and constant value. More details about the technical characteristics and configuration of the manufactured versions are indicated in the passport documentation.

Technical characteristics: Mercury electricity meter

Using the Mercury-230 meter as an example, let's look at the main technical qualities:

  • Installed dimensions – 258 by 170 by 74 mm;
  • The weight of the device is about 1.5 kg;
  • The period after which the inspection must be done is 10 years;
  • The average length of work is 17 years;
  • Service life – 30 years;
  • Manufacturer's warranty – 3 years.

The functionality of this counter includes the fact that it not only records data, but also stores it, measures it and displays it on a liquid crystal display. In addition, it transmits reactive and active energy in accordance with each tariff, both for a certain period of time and for the entire period in total.

What kind of lighting do you prefer?

Built-in Chandelier

80221-20: Mercury 230AM Three-phase static electric energy meters - Manufacturers, suppliers and verifiers

Unlike disk electricity meters, with digital devices, when the zero and phase are reversed, the electricity consumption will still be recorded correctly. That is, it is impossible to “rewind” the readings.

Expert opinion

Viktor Pavlovich Strebizh, lighting and electrical expert

Any questions ask me, I will help!

Below is a table where, for clarity, several modifications from this model range are given with a description of the main technical characteristics. If there is something you don’t understand, write to me!

Mercury counters: varieties

For example, if you need to know the amount of energy consumed at tariff T1 for February, you need to subtract T1 January from T1 February. The difference is the cost of a certain tariff.

How to take readings from it is quite clear if you take a little time and carefully read what is written on the display. If you have another meter installed, you can also learn about the rules for recording readings from the article How to take readings from an electric meter. Many people are starting to use Mercury-230 electricity meters.

Old-style electricity meters are induction devices. They are characterized by a mechanical disk that spins on the front model of the device.

Three-phase and single-phase electricity meters from the availability of Mercury 230ART2, Mercury 230AM, Mercury 230AR, Mercury 202, Mercury 230ART, Any number of electricity meters produced by the Frunze plant, Energomera, Elster, Incotex, Ryazan plant with... Stopping Mercury meters with a pulse device without removing or interfering with the design of the device itself. Stopping Mercury counters..

How to take readings from the Mercury 230 electricity meter

Taking readings from a single-tariff Mercury meter is not so difficult. To do this, pay attention to the 6-digit dial and write down all the signs up to the decimal point. In order to find out what indicator you received for the current period, subtract from the current data those that were taken last time.

As for taking readings from a multi-tariff meter, first you need to write down some readings.

Taking readings from multi-tariff Mercury occurs as follows:

  1. Make sure the meter is in ready mode. In order to check this, you need to look in the upper left corner and find the line there at the “A” mark. If it is not there, then you will need to switch the counter to the required mode.
  2. Switching to ready mode is done by pressing the button on the right. Most often it is located next to the “enter” button.
  3. After the mode is activated, we select indicators. The change is made using the "Enter" button.
  4. The first indicator that appears on the display is the energy consumption during the daytime; by pressing the key again, we will get the indicator for the night.

That's all, now you can issue a payment receipt and pay for electricity.

The electrical power of the meter is converted into an analog signal, which once again goes through the conversion process, but this time into a pulse signal. The main element of the electric meter is a microcontroller, which analyzes all signals and calculates the amount of energy consumed.

Also, with the help of this device, information is transmitted to output devices. As for induction meters, they consist of the following elements: an aluminum disk, a voltage coil, a calculation mechanism and a permanent magnet.

Induction

These devices are familiar to many of its users thanks to their glass window, behind which a special disk spins. The speed of its turnover depends on the amount of energy consumed. This type of electric meter is no longer relevant, as it is being forced out of the market by various modern analogues.

Due to its unprofitability, no one installs it now. Induction devices have more disadvantages than advantages, because their design does not allow automation of accounting and, under the influence of certain factors, can distort their readings.

Along with the use, the production of induction meters has also decreased. The reason for this is the preference for newer and more modern types of electricity meters.

Digital

These are newer devices that have become very popular today.

Compared to the previous type, digital electricity meters have many advantages:

All about electricians: power supply, electrical equipment, electrical installation

The uninterrupted operation of the electrical appliance allows you to record consumption both during the day and at night. By comparing the readings of the previous payment on the meter with the new data and carrying out simple calculations, the consumer pays for electricity.

Let's find out how to take readings from a multi-tariff meter (article Mercury 230 ART-01). To do this, you need to record the following data: T1 – current consumption during the day, T2 – current consumption at night. Before recording data, you must make sure that the device is in ready mode.

Can you tell me in Linux, when connecting Mercury 221, the device /dev/ttyUSB0 appears, is this enough or is a special driver still needed?

When the meter is connected to three-phase consumers, the process is carried out through current transformers. This scheme makes it possible to reduce the cost of electricity and increase the reliability of its supply. Direct connection meters do not make more than 100 A. This is due to the limitation of conductor sizes. The higher the current, the larger the cross-section of the wire required to pass it.

Functionality

  • determination, recording and display on the liquid crystal display of information on electricity, including active and reactive in the total, separately for each of the 36 past months or 120 days;
  • division into four prices and 16 zones with the possibility of individual settings for any month;
  • determination of energy losses in the network;
  • output of data on auxiliary current, power characteristics, voltage;
  • archiving information separately for each type of electricity;
  • recording peak loads in the morning and evening hours;
  • recording the most important events in the journal;
  • control and management of quality indicators.

We recommend: Electricity meter Neva 123 - instructions and how to take readings

The device is made in full compliance with state standards established for such products.

Execution optionRated voltage, VRated (maximum) current, AAccuracy class of active (reactive) energyCommunication interface
AR-01 M(CL)3*230/4005(60)1,0(2,0)CAN, PLC-I
AR-02 M(CL)3*230/40010(100)1,0(2,0)CAN, PLC-I
AR-03 M(CL)3*230/4005(7,5)0.5S(1.0)CAN, PLC-I

Expert opinion

Viktor Pavlovich Strebizh, lighting and electrical expert

Any questions ask me, I will help!

The operating principle of the meters is based on the conversion of input signals of AC power and voltage from analogue to digital form, followed by calculation of the amount of active electricity and its display on an electromechanical reading device. If there is something you don’t understand, write to me!

Advantages of the device

The electric meter has the following advantages:

  • reliability of the design;
  • the ability to take into account parameters at 4 tariffs in 16 time zones;
  • taking into account indicators on an increasing basis, regardless of the direction of the electric current;
  • the presence of protection against theft of electricity through a magnet;
  • automatic self-diagnosis with display of malfunctions and operational errors through indication;
  • the ability to control the load through external circuits;
  • a wide range of measured indicators;
  • possibility of direct connection;
  • compact sizes.

Overall dimensions of the Mercury 231 meter

The device provides the ability to record basic parameters in a log and then display them on external media.

Choosing an electric meter

Currently, Incotex has stopped producing devices operating on the induction principle, so only electronic modules are available for purchase.

It makes sense to purchase multi-tariff devices only if such a payment scheme is used in the region of residence and it is possible to use household appliances at night.

There is no point in purchasing a model capable of transmitting readings to the electric company if the latter does not have this capability.

It is debatable how necessary it is to purchase a device, for example, the 201 series, where after installing special software, it becomes possible to call the office to obtain detailed information. Additional modules that make up such an electric meter lead to a significant increase in the cost of the device. Again, as practice shows, the simpler the device, the longer it will last.

Now let's move on from general advice to specifics:

  • Each Mercury electricity meter must be equipped with a passport and technical documentation, which indicates the capacity of the electricity meter, a description of how it works, a connection diagram and other useful information. The technical documentation should include an operating manual that describes in detail how to correctly take readings, information about the verification interval, etc.

In the absence of a passport, the device will not be able to be registered and, accordingly, operation will be impossible.

  • There must be a hologram on the electric meter, as well as a factory seal.
  • Compare the signs and numbers on the electric meter with the serial number indicated in the passport.
  • Check that the warranty card is filled out correctly, otherwise the warranty for the electric meter may be invalidated. If such a device fails or does not work correctly (for example, it overestimates the significance of the readings, beeps, consumes a lot of energy from an additional source, etc.), then problems may arise with its replacement or repair.

Please note that inflated readings (the device has more kW than it actually consumes) are not uncommon. This indicates that the device is not adjusted correctly.

Expert opinion

Viktor Pavlovich Strebizh, lighting and electrical expert

Any questions ask me, I will help!

In the described situation, the exception is modifications of the 234 series; instructions for this procedure are available in the passport for the electric meter. If there is something you don’t understand, write to me!

Mercury 230 - electric meter review, characteristics

Meters of this model are currently being produced. The price for Mercury 230 starts from 2300 rubles.

Some meters have only a whole part of kilowatt-hours on the drum of the counting mechanism, while others, in addition to the whole part, have a fraction of kilowatt-hours, which do not need to be taken into account when taking readings.

You can always support the author of the channel financially. Sberbank card: 5469 6000 1637 3656 Roman Viktorovich B. I would be very grateful. Matrix NP73E.3..

Especially for you, I have compiled tables for the most common single-phase and three-phase Energomer meters (data taken from the operating manuals), where the exact position of the decimal point is indicated.

Purpose

Three-phase static electric energy meters “Mercury 230AM”, “Mercury 230AM” (hereinafter referred to as meters), are designed for measuring and accounting for active electrical energy of alternating current in three and four-wire alternating current networks with a frequency of 50 Hz.

The operating principle of the meters is based on the conversion of input signals of AC power and voltage from analogue to digital form, followed by calculation of the amount of active electricity and its display on an electromechanical reading device.

The meters provide registration and storage of electricity consumption values ​​at one tariff from the moment of commissioning.

The meters can be operated either autonomously or as part of an automated data collection system.

The meters are intended for indoor use, and can also be used in places that have additional protection from environmental influences (installed indoors, in a cabinet, in a panel).

The meters have a built-in electromechanical reading device (hereinafter referred to as the CU) to display the measured electricity.

The meters are produced with different brands: “Mercury” - for sales with a Russian-language trademark and “Mercury” - for sales with an English-language trademark. Metrological and technical characteristics apply to both brands.

The meters are available in the following modifications: “Mercury 230AM-00”, “Mercury 230AM-01”, “Mercury 230AM-02” , “Mercury 230AM-03” (“Mercury 230AM-03”), differing in base (nominal) and maximum current, rated voltage, accuracy class and meter constant. Distinctive features of meters of various modifications are given in Table 1.

Basic data
State Register number80221-20
NameThree-phase static electricity meters
ModelMercury 230AM
Interverification interval / Verification frequency10 years
Manufacturer countryRUSSIA
Certificate period (Or serial number)23.12.2025

Basic and additional functions

Let's look at how to take readings from an electricity meter. The device has a 6-digit dial. You need to write down all the numbers up to the decimal point. To calculate energy consumption for a month, you need to subtract from the new readings those that were last month.

Expert opinion

Viktor Pavlovich Strebizh, lighting and electrical expert

Any questions ask me, I will help!

The standard telemetry output allows you to operate an electricity meter as part of an automated accounting system that has the ability to receive accounting information in telemetry pulses; Execution options. If there is something you don’t understand, write to me!

We take readings from a single-tariff meter Mercury 230


Popular types of single-tariff electricity meters: Mercury 230 AR/AM1 Mercury 230 AR/AM02 Mercury 230 AR/AM03
In order to record the readings of a single-tariff Mercury meter, look at the 6-digit dial and write down the numbers to the decimal point.

To determine the meter readings for the last month, subtract the readings that were a month ago from the current latest meter readings.

Meter with built-in computer

Electronic meters are produced without a rotating wheel, with installed digital displays. Due to their versatility, they have a standard menu where additional settings are located.

The latest models of electricity meters are much better equipped. Several phases can be summed up to them. This is very convenient considering that many consumers switch to two or three tariff plans:

All additional settings allow you to find out in more detail information about consumption at a certain time of day, the operating time of the meter and data on the readings T1 and T2.

The consumer's first impression is that it will be difficult to read information from an electronic meter. To do this, you need to study the manual for the electrical appliance or consult an electrician.

In addition, there are models that do not need to regularly take readings. They are connected to a common central network and send readings to a server at the power company. And you just receive a monthly electricity bill.

The gradual introduction of two-tariff energy metering allows saving on electricity, especially in apartment buildings, as well as optimally distributing energy. But here it’s also worth considering at what hours your consumption is greater and at which times it is less. If daytime consumption is small, and the main load occurs at night, then the Mercury 230 model is perfect.

Expert opinion

Viktor Pavlovich Strebizh, lighting and electrical expert

Any questions ask me, I will help!

Hybrid meters are not very convenient, since their measuring part is electrical, and their computing part is mechanical. If there is something you don’t understand, write to me!

Digital

  • in the display mode of consumed electricity;
  • in the mode of recording the indication of maximum power;
  • in the display mode of the current values ​​of auxiliary parameters (instantaneous values ​​of active, reactive and apparent power, both in each phase and the sum, current in each phase, voltage in each phase, cos ϕ in each phase and in sum, network frequency, and for meters with an internal tariff (additionally - current time and date).

Useful tips Connection diagrams Principles of operation of devices Main concepts Meters from Energomer Precautions Incandescent lamps Video instructions for the master Testing with a multimeter

Mercury 230. Operating procedure. Reading information from the meter indicator using buttons

The values ​​of metered energy by tariff zones can be read both from the meter indicator using the buttons on the front panel, and through the CAN interface (or RS-485 or IrDA or GSM modem). At the top of the LCD there are elements that indicate the type of energy: A+, A-, R+, R-, day, month, year, previous year and losses (Note - inscriptions can be in both Russian and English).

Reading information from the Mercury 230 meter indicator using buttons

When the counter is turned on, within 1.5 s, all indication elements are turned on: cursors, icons and all segments of digital indicators. After which the counter goes into the display mode of current measurements. The LCD of the counter during its operation when using the keys can be in one of three modes:

  • in the display mode of consumed electricity;
  • in the mode of recording the indication of maximum power;
  • in the display mode of the current values ​​of auxiliary parameters (instantaneous values ​​of active, reactive and apparent power, both in each phase and the sum, current in each phase, voltage in each phase, cos ϕ in each phase and in sum, network frequency, and for meters with an internal tariff (additionally - current time and date).

Display mode of accumulated energy according to current tariffs.

When the meter is turned on, the liquid crystal display (hereinafter referred to as LCD) shows the amount of active energy consumed at the current tariff for the entire period of operation of the meter. This value is displayed in kWh, with a resolution of 0.01 kWh (two decimal places). To the right of this number are the units in which the displayed value is expressed (kW⋅h). The number of the current tariff is shown on the left (T1 is the first tariff, T2 is the second, T3 is the third, T4 is the fourth). At the top of the LCD there are elements that indicate the type of energy: A+, A-, R+, R-.

The counter has two indication modes: manual and automatic.

In automatic mode, the LCD screen sequentially displays information about the accumulated active and reactive energy for each tariff and the sum for all tariffs for each type of energy. The number of parameters is no more than 12 and no less than one and is programmed using the “Configurator...” program. The duration of parameter display is also set by the “Configurator...” program. In manual mode, when you press the “ENTER” key, the information on the LCD changes cyclically as follows: the sum of the accumulated active energy at all current tariffs, then the next time you press the “ENTER” key, the amount of accumulated active energy at tariff 1 is indicated, indicating the tariff number, with further By pressing the “ENTER” key, the amount of accumulated active energy according to tariffs 2, 3, 4 is sequentially displayed, indicating the tariff number. After the last tariff (if the meter is four-tariff, then after the fourth, if three-tariff - after the third, if two-tariff - after the second), the amount of accumulated reactive energy at all current tariffs is displayed, the subsequent pressing of the “ENTER” key displays the amount of accumulated reactive energy at tariff 1 with an indication tariff numbers. When you further press the “ENTER” key, the amount of accumulated reactive energy according to tariffs 2, 3, 4 is sequentially displayed, indicating the tariff number. In this case, the number of the displayed tariff is displayed on the left, and if the amount is displayed, then the inscription “Amount” appears in the lower part. The amount of information displayed on the LCD is determined by the configurator, but does not exceed more than 12 parameters and at least one. For electricity meters with software version 2.2.83 and higher (production began on 04/07/2008), information on all tariffs and on all types of energy (active, reactive) is displayed manually on the LCD. The ability to change this indication mode using the “Configurator …” program is blocked at the electric meter level.

Indication of auxiliary parameters.

When you briefly press the “” key, auxiliary parameters are displayed on the LCD screen in the following sequence: active power (W) – reactive power (VAr) – apparent power (VA) – network voltage (V) – angle between phases – load current (A) – cos ϕ – network frequency (Hz), and for meters with an internal rater – current time (s) – current date. The parameter is selected by pressing the “” key for a long time (more than 3 seconds). When you briefly press the “” key, the total parameter value and for each phase separately are displayed on the LCD screen. When indicating network voltage and current, the total value is not indicated. If during the timeout for returning to automatic mode (5÷255 s) the “” button is not pressed, the indicator goes into automatic indication mode.

Power peak indication

When you press the “ENTER” button for a long time (more than 2 seconds), the LCD screen displays the current month in the “month _ year” format. Next, short presses of the “ENTER” button lead to sequential display of morning and evening power maximums for the current month on the LCD. You can also look at the previous three months. When displaying morning maximum power, symbols T1 and T2 are displayed, evening maximums – T3 and T4. The type of power is indicated at the top with the symbol “-” in the appropriate place.

Manual clock correction mode.

Clock correction is carried out in the current time display mode. By long pressing (more than 3 seconds) and releasing the “ENTER” button, the current time is corrected. In this case, if the value of the seconds of the current time is less than 30 seconds, the moment the “ENTER” button is released, the seconds of the current time are reset to zero; if the value of the seconds of the current time is more than 29 seconds, at the moment the “ENTER” button is released, the value of the seconds of the current time is set to 59 seconds. Implementation of maximum correction of the current time up to ±29 sec. perhaps once a day.